Connection handling
Get connection settings
- GET /api/connection
Retrieve the current connection settings, including information regarding the available baudrates and serial ports and the current connection state.
Requires the
STATUS
permission.Example
GET /api/connection HTTP/1.1 Host: example.com X-Api-Key: abcdef...
HTTP/1.1 200 OK Content-Type: application/json { "current": { "state": "Operational", "port": "/dev/ttyACM0", "baudrate": 250000, "printerProfile": "_default" }, "options": { "ports": ["/dev/ttyACM0", "VIRTUAL"], "baudrates": [250000, 230400, 115200, 57600, 38400, 19200, 9600], "printerProfiles": [{"name": "Default", "id": "_default"}], "portPreference": "/dev/ttyACM0", "baudratePreference": 250000, "printerProfilePreference": "_default", "autoconnect": true } }
- Status Codes:
200 OK – No error
Issue a connection command
- POST /api/connection
Issue a connection command. Currently available command are:
- connect
Instructs OctoPrint to connect or, if already connected, reconnect to the printer. Additional parameters are:
port
: Optional, specific port to connect to. If not set the currentportPreference
will be used, or if no preference is available auto detection will be attempted.baudrate
: Optional, specific baudrate to connect with. If not set the currentbaudratePreference
will be used, or if no preference is available auto detection will be attempted.printerProfile
Optional, specific printer profile to use for connection. If not set the current default printer profile will be used.save
: Optional, whether to save the request’sport
andbaudrate
settings as new preferences. Defaults tofalse
if not set.autoconnect
: Optional, whether to automatically connect to the printer on OctoPrint’s startup in the future. If not set no changes will be made to the current configuration.
- disconnect
Instructs OctoPrint to disconnect from the printer.
- fake_ack
Fakes an acknowledgment message for OctoPrint in case one got lost on the serial line and the communication with the printer since stalled. This should only be used in “emergencies” (e.g. to save prints), the reason for the lost acknowledgment should always be properly investigated and removed instead of depending on this “symptom solver”.
Requires the
CONNECTION
permission.Example Connect Request
POST /api/connection HTTP/1.1 Host: example.com Content-Type: application/json X-Api-Key: abcdef... { "command": "connect", "port": "/dev/ttyACM0", "baudrate": 115200, "printerProfile": "my_printer_profile", "save": true, "autoconnect": true }
HTTP/1.1 204 No Content
Example Disconnect Request
POST /api/connection HTTP/1.1 Host: example.com Content-Type: application/json X-Api-Key: abcdef... { "command": "disconnect" }
HTTP/1.1 204 No Content
Example FakeAck Request
POST /api/connection HTTP/1.1 Host: example.com Content-Type: application/json X-Api-Key: abcdef... { "command": "fake_ack" }
HTTP/1.1 204 No Content
- JSON Parameters:
command (string) – The command to issue, either
connect
,disconnect
orfake_ack
.port (string) –
connect
command: The port to connect to. If left out either the existingportPreference
will be used, or if that is not available OctoPrint will attempt auto detection. Must be part of the available ports.baudrate (number) –
connect
command: The baudrate to connect with. If left out either the existingbaudratePreference
will be used, or if that is not available OctoPrint will attempt autodetection. Must be part of the available baudrates.printerProfile (string) –
connect
command: The id of the printer profile to use for the connection. If left out the current default printer profile will be used. Must be part of the available printer profiles.save (boolean) –
connect
command: Whether to save the supplied connection settings as the new preference. Defaults tofalse
if not set.autoconnect (boolean) –
connect
command: Whether to attempt to automatically connect to the printer on server startup. If not set no changes will be made to the current setting.
- Status Codes:
204 No Content – No error
400 Bad Request – If the selected port or baudrate for a
connect